List of Vietnam Law
Decision No. 24/2018/QD-TTg dated May 18, 2018 of the Prime Minister promulgating the list of low-efficiency equipment that has to be discarded and low-efficiency generating sets that are prohibited from being built, and the roadmap to implementation thereof
Date: 5/18/2018
THE PRIME MINISTER
------- |
THE SOCIALIST REPUBLIC OF VIETNAM
Independence - Freedom - Happiness --------------- |
No. 24/2018/QD-TTg
|
Hanoi, May 18, 2018
|
|
PP. THE PRIME MINISTER
THE DEPUTY MINISTER (Signed and sealed) Trinh Dinh Dung |
(Enclosed with the Decision No. 24/2018/QD-TTg dated May 18, 2018 of the Prime Minister)
No.
|
Name
|
National standards
|
I. Home appliances:
|
||
1
|
Compact fluorescent lamps
|
TCVNCVN 7896:2008
|
2
|
Electronic ballasts for fluorescent lamps
|
TCVN 7897:2008
|
3
|
Electromagnetic ballasts for fluorescent lamps
|
TCVN 8248:2009
|
4
|
Linear tubular fluorescent lamps
|
TCVN 8249:2009
|
5
|
Electric fans
|
TCVN 7826:2007
|
6
|
Refrigerators and refrigerator freezers
|
TCVN 7828:2013
|
7
|
Non-ducted air conditioners
|
TCVN 7830:2015
|
8
|
Clothes washing machines for household use
|
TCVN 8526:2010
|
9
|
Television sets
|
TCVNCVN 9536:2012
|
10
|
Electric cookers
|
TCVN 8252:2009
|
11
|
Storage water heaters
|
TCVN 7898:2009
|
II. Office and commercial equipment
|
||
1
|
Computer monitors
|
TCVN 9508:2012
|
2
|
Copiers
|
TCVN 9510:2012
|
3
|
Printers
|
TCVN 9509:2012
|
4
|
Commercial refrigerated cabinets
|
TCVN 10289:2014
|
III. Industrial equipment:
|
||
1
|
Three-phase asynchronous squirrel cage electrical motors
|
TCVN 7540-1:2013
|
2
|
Distribution transformers
|
TCVN 8525:2010
|
3
|
Boilers used in industrial workshops
|
TCVN 8630:2010
|
(Enclosed with the Decision No. 24/2018/QD-TTg dated May 18, 2018 of the Prime Minister)
No.
|
Name
|
National standards
|
I. Home appliances:
|
||
1
|
Compact fluorescent lamps
|
TCVN 7896:2015
|
2
|
Electronic ballasts for fluorescent lamps
|
TCVN 7897:2013
|
3
|
Electromagnetic ballasts for fluorescent lamps
|
TCVN 8248:2013
|
4
|
Linear tubular fluorescent lamps
|
TCVN 8249:2013
|
5
|
Electric fans
|
TCVN 7826:2015
|
6
|
Refrigerators and refrigerator freezers
|
TCVN 7828:2013
|
7
|
Non-ducted air conditioners
|
TCVN 7830:2015
|
8
|
Clothes washing machines for household use
|
TCVN 8526:2013
|
9
|
Television sets
|
TCVN 9536:2012
|
10
|
Electric cookers
|
TCVN 8252:2015
|
11
|
Storage water heaters
|
TCVN 7898:2009
|
II. Office and commercial equipment:
|
||
1
|
Computer monitors
|
TCVN 9508:2012
|
2
|
Copiers
|
TCVN 9510:2012
|
3
|
Printers
|
TCVN 9509:2012
|
4
|
Commercial refrigerated cabinets
|
TCVN 10289:2014
|
III. Industrial equipment:
|
||
1
|
Three-phase asynchronous squirrel cage electrical motors
|
TCVN 7540-1:2013
|
2
|
Distribution transformers
|
TCVN 8525:2015
|
3
|
Boilers used in industrial workshops
|
TCVN 8630:2010
|
(Enclosed with the Decision No. 24/2018/QD-TTg dated May 18, 2018 of the Prime Minister)
No.
|
Generating sets
|
Efficiency (%)
|
I. Minimum efficiency of coal-fired generating sets that is determined according to the lower heating value at rated capacity of the generating set with coolant temperature of 28°C and ambient temperature of 30°C:
|
||
1
|
50 MW ≤ capacity < 150 MW
|
34.0
|
2
|
150 MW ≤ capacity < 300 MW
|
38.0
|
3
|
300 MW ≤ capacity < 600 MW
|
39.0
|
4
|
600 MW ≤ capacity < 800 MW
|
41.0
|
5
|
Capacity ≥ 800 MW
|
43.0
|
II. Regarding gas-fired generating sets that use simple cycle gas turbines, the efficiency of the gas turbine assembly (under ISO standard conditions) must not fall below the following values:
|
||
1
|
100 MW ≤ capacity < 150 MW
|
33.0
|
2
|
150 MW ≤ capacity < 200 MW
|
34.0
|
3
|
200 MW ≤ capacity < 300 MW
|
37.0
|
4
|
Capacity ≥ 300 MW
|
39.0
|
III. Regarding gas-fired generating sets that use combined cycle gas turbines, the efficiency of the combined cycle gas turbine assembly (under ISO standard conditions) that is determined according to the capacity of the simple cycle gas turbine must not fall below the following values:
|
||
1
|
100 MW ≤ capacity < 150 MW
|
49.5
|
2
|
150 MW ≤ capacity < 200 MW
|
51.0
|
3
|
200 MW ≤ capacity < 300 MW
|
55.5
|
4
|
Capacity ≥ 300 MW
|
58.5
|